
Flame Retardant PP FR-1401
Tensile strength 23 MPa, Notched impact strength 60 J/m.
Request Data Sheet & Quote →Modified PP CP111. Tensile strength 28 MPa, Notched impact 160 J/m. MOQ 500 kg.

| Property | Unit | Typical value |
|---|---|---|
| Density (23℃) | g/cm³ | 0.9 |
| Mould shrinkage (23℃) | % | 1.4-1.6 |
| MFR (230℃/2.16kg) | g/10min | 1.5 |
| Tensile strength (50mm/min) | MPa | 28 |
| Flexural strength (2.0mm/min) | MPa | 28 |
| Flexural modulus (2.0mm/min) | MPa | 950 |
| Notched impact strength (23℃) | J/m | 160 |
| HDT (0.45MPa) | °C | 90 |
| Flammability (3.0) | — | HB |
| Parameter | Recommended |
|---|---|
| Drying | — |
| Rear zone temperature | — |
| Middle zone temperature | — |
| Front zone temperature | — |
| Nozzle temperature | — |
| Melt temperature | — |
| Mould temperature | — |

Tensile strength 23 MPa, Notched impact strength 60 J/m.
Request Data Sheet & Quote →
Tensile strength 21 MPa, Notched impact strength 190 J/m.
Request Data Sheet & Quote →
Tensile strength 26 MPa, Notched impact strength 48 kJ/m².
Request Data Sheet & Quote →
Tensile strength 19 MPa, Notched impact strength 37 J/m.
Request Data Sheet & Quote →Tell us the wall thickness, service temperature and volume, and we will come back within 24 hours with a technical recommendation and pricing.
Yes. Send us the incumbent grade and the critical values (tensile strength, impact at −30 °C, shrinkage, colour) and we match the formulation to those targets. Most customers validate with a 5–25 kg sample before switching production.
Fibre length retention and the coupling system. We control shear on twin-screw lines and test every lot for MFR, ash, tensile and impact; each lot ships with a COA for traceability.