Glass Fibre Reinforced PSU RF-6032GF20
Tensile strength 95 MPa, Notched impact strength 50 J/m.
Request Data Sheet & Quote →Reinforced AS RF-3031GM20. Tensile strength 82 MPa, Notched impact 65 J/m. MOQ 500 kg.

| Property | Unit | Typical value |
|---|---|---|
| Density (23℃) | g/cm³ | 1.22 |
| MFR (220℃/10kg) | g/10min | 15.6 |
| Tensile strength (50mm/min) | MPa | 82 |
| Elongation at break (50mm/min) | % | 2 |
| Flexural strength (2.0mm/min) | MPa | 115 |
| Flexural modulus (2.0mm/min) | MPa | 5300 |
| Notched impact strength (23℃) | J/m | 65 |
| HDT (1.82MPa) | °C | 112 |
| Flammability (1.5mm) | — | HB |
| Parameter | Recommended |
|---|---|
| Drying | 100℃, 2-4h |
| Rear zone temperature | 200℃-220℃ |
| Middle zone temperature | 210℃~230℃ |
| Front zone temperature | 220℃~240℃ |
| Nozzle temperature | 20℃~240℃ |
| Melt temperature | 220℃-240℃ |
| Mould temperature | 70℃-90℃ |

Tensile strength 95 MPa, Notched impact strength 50 J/m.
Request Data Sheet & Quote →
Tensile strength 110 MPa, Notched impact strength 63 J/m.
Request Data Sheet & Quote →
Tensile strength 90 MPa, Notched impact strength 110 J/m.
Request Data Sheet & Quote →
Tensile strength 95 MPa, Notched impact strength 145 J/m.
Request Data Sheet & Quote →Tell us the wall thickness, service temperature and volume, and we will come back within 24 hours with a technical recommendation and pricing.
Yes. Send us the incumbent grade and the critical values (tensile strength, impact at −30 °C, shrinkage, colour) and we match the formulation to those targets. Most customers validate with a 5–25 kg sample before switching production.
Fibre length retention and the coupling system. We control shear on twin-screw lines and test every lot for MFR, ash, tensile and impact; each lot ships with a COA for traceability.